Hi LB, and welcome,
If the Channel led indicators are not working then the issue may well be in the switching circuit, (RL1 at top of drawing)
The relay contacts maybe faulty or power not going to B (the 1k5 1W resistor)..
Should be over 50VDC at B. Then at the relay should be 12VDC controlled by the 12V Zener.
Oh and your sand box resistors are fine, that is just the filler crumbling nothing to worry about.
HTH, Phil.

If the Channel led indicators are not working then the issue may well be in the switching circuit, (RL1 at top of drawing)
The relay contacts maybe faulty or power not going to B (the 1k5 1W resistor)..
Should be over 50VDC at B. Then at the relay should be 12VDC controlled by the 12V Zener.
Oh and your sand box resistors are fine, that is just the filler crumbling nothing to worry about.
HTH, Phil.